ROCKWOOL FIBERTEX 650 SPI
SECTION PIPE INSULATION

Product Description
Fibertex-650 SPI (Sectional Pipe Insulation) consists of fine fibres spun from molten natural rock resin-bonded preformed into pipe cover. The sections are moulded to ensure a firm fit around the pipe and the outer surface is ground to ensure the precision of insulation thickness and a smooth, even surface.

Fibertex-650 SPI is a heavy duty pipe insulation for hot-faced temperature up to 650 oC, and supplied as one-piece section of convenient length. Each section is split and hinged for easy, snap-on application by opening the slit and springing it in position as pipe cover.

Applications
Fibertex-650 SPI is suitable for both hot and cold piping to maintain process temperatures, provide personal protection, prevent condensation and reduce noise transmission. It can also be used in central-heating and air-conditioning systems.

Fibertex-650 SPI should be retained by wire mesh or metel bands as per manufacturers instructions and protected by metal cladding, mastic or other coating. Detailed installations are available from CSR offices.

Nominal Density
120, 150 kg/m 3 (7 , 9 3/8 lb/ft 3)

Maximum Service Temperature
Recommended operating temperature up to 650 C (1202 F)
Capability of handling intermittent temperature up to 1000 C (1832 F)

Fusion Temperature
Fusion temperature or Melting point of rockwool at 1350 C (2462 F)

Thermal Conductivity 
0.034 W/mK at 20 C mean temperature
(0.235 BTU in/ft 2h F at 68 F)

Thermal conductivity of Fibertex-650 SPI varies with the mean temperature as shown in graph according to BS 874-1973.

Insulation performance requirements may be specified in many different ways such as Thermal conductivity, Thermal resistance, Process temperature, Allowable surface temperature or Heat loss.

CSR Application Engineers will provide technical services and more details to meet any specification.

Factory Applied Facings
Fibertex-650 SPI is available to order without facing or with wide ranges of factory applied facings such as aluminium foil, calico, reinforced foil laminate (vapor seal).

Other facings are available to order but may be subject to minimum order quantity.

Fire Performance
Fibertex-650 SPI achieves four zero Early Fire Hazard Indices when tested in accordance with AS 1530:Part 3-1976 (same as BS 476 : Part 5, 6, 7-1967) for non-combustible material.

Moisture Resistance
Exposure to an atmosphere of 50 oC and 95% relative humidity for 96 hours results in moisture absorption of less than 0.2% by volume. Should insulation become wet, full thermal efficiency will be restored on drying out.

Water repellent grade according to BS 2792 section 12 is available to order.

Corrosion Resistance
Fibertex-650 SPI is faintly alkaline and is incapable of corroding steel, copper, or aluminium. To maintain this condition, protection must be provided against contamination from external sources. When tested in accordance with BS 3958 : Part 5-1969, results in range of pH 7.5 8.0. Fibertex-650 SPI contains less than 15ppm soluble chlorides. For critical applications involving austenitic stainless steel, a low chloride formulation is available to order which is less than 6ppm.

< กลับหน้าหลัก Rockwool
CSR Bradford Insulation Fibertex 450
Acoustic Properties

When tested in a reverberation chamber in accordance with AS 1045-1971 sound absorption coefficients of Fibertex-650 are shown in the table:

Thickness (mm.) NRC
25 0.69
50 0.97

NRC is the average sound absorption coefficient between 250 to 2000 Hz

Standard Size and Packing
Pipe Insulation
 Pipe OD (mm.) Thickness (mm.)
21.3 711.0 25, 30, 40, 50, 60
70, 80, 90, 100
* Length / piece 1.20 m.
* Not all wall thickness are available ex-stock for every pipe size.

Note : Two dimensions must be specified when ordering pipe insulation the outside diameter of the pipe and the insulation thickness.

- Pipes manufactured to different dimensional standards (i.e. steam, API, copper, etc) differ in outside diameter for a given nominal bore. To avoid costly mistakes, it is essential to make certain of the pipe O.D. before placing the pipe insulation order.

- Standard packaging cardboard cartons, or shrink-wrapped polythene as appropriate. The number of sections per pack depends on the size of each sections.