Factory Applied Facings
Product is available to order with ranges of factory applied facings such as various grades of aluminium foil, glass cloth, glass matt, polyester laminate.
Fire Performance
Bradford Rockwool achieve four zero of Early Fire Hazard Indices when tested with AS 1530 : Part 3-1976 (same as BS 476 : Parts 5, 6, and 7;1967) for non-combustible material.
Moisture Resistance
Exposure to an atmosphere of 50 oC and 95% relative humidity for 96 hours results in moisture absorption of less than 0.2% by volume. Should insulation become wet, full thermal efficiency will be restored on drying out.
Corrosion Resistance
Fibertex-R120 is faintly alkaline and not accelerated with steel, copper or aluminum. When tested in accordance with BS 3958: Part 5 : 1969, results in range of pH 7.5 to 8.0. Fibertex-R120 contain less than 15ppm soluble chlorides.
Compression Resistance
Fibertex-R120 is a resilient material which readily returns to original shape after removal load. The result between reduction in thickness (%) versus compressive load (kPa) following BS-2972 ; 1975 :
|